Hand-Carried Ultrasound

Product Specifications
Hand-Carried UltrasoundDifference contrast
  •   
  •   Product name Hand-Carried Ultrasound
  • Technical parameter The following parameters are described as the main version of the animal version  
  • Application scope pig, dog, cat, cow, sheep, horse  
  • Scanning Method Intracavity probe center frequency is 6.5MHz, frequency range is 5.0-8.5MHz, 4 frequency onversions (3/3.5/4.0/5.0MHz) (diagnosis of animal gestation, there are already probes)  
  •   Convex array probe center frequency is 3.5MHz, frequency range is 3.0-5.0MHz, 4 frequency conversions (3/3.5/4.0/5.0MHz) (diagnosis of abdomen, there are already probes)  
  •   Line array probe center frequency is 7.5MHz, frequency range is 5.0-10.0MHz, 4 frequency conversions (5.5/7.5/9.0/10.0MHz)  
  •   High-frequency convex probe center frequency is 6.5MHz, frequency range is 5.0-8.5MHz, 4 frequency conversions (5/6.5/7.0/8.5MHz)  
  •   Low-frequency convex probe center frequency is 6.5MHz, frequency range is 5.0-8.5MHz, 4 frequency conversions (3/3.5/4.0/5.0MHz)  
  •   Large animal rectal probe center frequency is 7.5MHz, frequency range is 5.0-10.0MHz, 4 frequency conversions (5.5/7.5/9.0/10.0MHz)  
  •   PS Probe has automatic freeze function (automatic freeze time can be preset.)  
  • Imaging mode B、2B、4B、M  
  • power supply power input Voltage: 100-240V
    Frequency: 50/60Hz
    Power: 42VA  
  •   power working time Network power: ≥ 8h
    frequency internal voltage ≥ 2h  
  • In-output devices USB interface
    TV-OUT (Composite Video Interface)
    Power line interface  
  • Human-computer interaction system Number of control panel cases 5
    Touch screen
    Monitor size:7 inch TFT LCD  
  • Graphic information management Movie return visit Supports B, M mode movie playback
    Support manual and automatic playback
    Movie playback frames: 512 frames  
  •   Image storage Static Image: JPG
    Storage capacity: 1200 frames
    Support: USB and other mobile storage devices
    Revisit speed: 4 levels adjustable (1, 1/2, 4/1, 8/1)  
  • B, M mode scan parameters Gain 0-100dB, Step: 3dB  
  •   Near-field gain 0-100dB, step length: 3dB  
  •   Far-field gain 0-100dB, step length: 3dB  
  •   Dynamic Range 30-50dB, Stepping: 5dB  
  •   Gray-scale diagram 16 kinds of adjustable (A-P)  
  •   Frequency divided into four frequency adjustable  
  •   Depth The maximum depth can reach 32cm  
  •   Number of focal points 4 adjustable (1,2,3,4)  
  •   Depth of focus The maximum depth of up to 12cm  
  •   Line density: H, L two files  
  •   Smooth 4-speed adjustable (1,2,3,4)  
  •   Frame related 8-speed adjustable (0-7)  
  •   Edge Enhancement 4-speed adjustable (0,1,2,3)  
  •   Up and down The image flips upside down  
  •   B/M layout up/down  
  •   B/M layout ratio 50/50  
  •   Scan depth large convex probe, 2.5-31cm  
  •   visible Full field, low density, depth 18.5cm, frame rate 60.1 frames  
  • Conventional measurement and calculation B mode conventional measurement Distance
    Perimeter/area: ellipse, tracing
    Angle
    Volume: three-distance method, one-distance method, ellipse + ellipse  
  •   M mode conventional measurement Slope
    Heart rate  

Hand-Carried Ultrasound Related Video: